(HMDigital LBS-10)

(SAVANT AS-414)
Leak controller – solenoid and front control element.

(SAVANT AS-414)

(HMDigital LBS-10)
Leak controller – solenoid and back control element.

(HMDigital LBS-10)

(SAVANT AS-414)
Wipe the sensor – make sure that the wiping cloth is dry.
When a leak occurs the
LeakBlock Sensor will latch
the solenoid closed and
sound “Beep-Beep-Beep”.
The alarm will continue
until LBS-10 LeakBlock
Sensor is Reset.

Press once on the “Close” button. (HMDigital LBS-10)

Press “Reset” button for 3 seconds. (HMDigital LBS-10)

Only press “Reset” button for 5 seconds. (SAVANT AS-414)
If a leak occurs Simply shut off the incoming water supply, first press “Close” button and after press “Reset” button for 3 seconds on the LeakBlock Sensor. A “Beep” will sound indicating the LeakBlock Sensor is ready for use. Make sure the surface where you place the LeakBlock Sensor is clean and dry.


Attention!
Pressing “Reset” button
Don’t touch the moisture sensor!
Parts
O-Ring 1/4″ (compatible with all Reverse Osmosis 1/4″ piping)
Commercial Water Softeners
Dual Tank On Demand 32,000 x 32,000 Grain Water Softener with Fleck 9100 SXT valve
Filtration Systems By Contaminants
3 Stage Water softener with Fleck 5800 SXT Upflow/Downflow Control Valve
Salt Free Water Softeners
Oxy Mag – Scale / Contaminant Reduction (OxyMag) 5800SXT
Filtration Systems By Contaminants
3 Stage Water softener with Clack WS1 Control Valve